Friday, April 11, 2008

Konfigure SU Nera 3.3 Ghz




Switch on power NERA, the Hyperterminal set to Default Setting (9600,8,N,1) Select Access Level

===================

1 - Read-Only

2 - Installer

3 - Administrator >>> 3 Enter password (up to 30 printable ASCII chars) Ø *******
Ketik password ‘private’.


NetLink/SU-A/E-BD Official Release Version - 4.1.34 Release Date: Sun Feb 02 16:21:33 2003 Main Menu =========

1 - Info Screens

2 - Unit Control

3 - Basic Configuration

4 - Site Survey

5 - Advanced Configuration

X - Exit >>>


Untuk menset prompt:

tekan 2 (the Control Unit), kemudian tekan 3 (Change Unit Name), Ketik prompt‘customer’.
Kemudian, untuk mengganti password Administrator:

tekan 4 (Change Password), kemudian tekan 3 (Change Administrator Password), lalu tulis passwordnya ‘xxxxxxx’, lalu ulangi lagi passwordnya ‘xxxxxxx’.


NetLink/SU-A/E-BD Official Release Version - 4.1.34 Release Date: Sun Feb 02 16:21:33 2003 Change Password ===============

1 - Change Read-Only Password

2 - Change Installer Password

3 - Change Administrator Password customer >>> 3 Enter password (up to 8 printable ASCII chars) > ******* Reenter Password Please:*******


Kembali ke main Menu, tekan Esc 2 kali

Untuk configure NERA: tekan3 (Basic Configuration) .

NetLink/SU-A/E-BD Official Release Version - 4.1.34 Release Date: Sun Feb 02 16:21:33 2003 Basic Configuration ===================

1 - IP Address

2 - Subnet Mask

3 - Default Gateway Address

4 - ESSID

5 - Maximum Data Rate D - DHCP Client F - Flexible Hopping Definition X - Transmit Power Control Y - Receive Attenuation Control A - ATPC Parameters B - Best AU Parameters V - VLAN Support U - Security Parameters N - Scanning Mode S - Show Basic Configuration customer >>>
For the IP Address set, pressed the figure 1 (IP Address), then put IP xxx.xxx.xxx.xxx.
For the set Subnet mask, pressed the figure 2, then put his subnet mask xxx.xxx.xxx.xxx.
For the Gateway set, pressed the figure 3 (Default Gateway Address), then put gateway xxx.xxx.xxx.xxx.
For the ESSID the set, pressed the figure 4 (ESSID) then put ESSID ‘xxxxx’. The ESSID naming in accordance with the direction antenna AU.
For the set of Maximum Data Rate, pressed the figure 5 (Maximum Data Rate), then pressed the figure 1 (1 Mbps).
For the set of his frequency, pressed the F letter (Flexible Hopping Definition), then pressed the figure 1 (Define Sub- Bands), then put the figure ‘3312-3324’.
Back to the main menu.
NetLink/SU-A/E-BD Official Release Version - 4.1.34 Release Date: Sun Feb 02 16:21:33 2003 Main Menu ========= 1 - Info Screens 2 - Unit Control 3 - Basic Configuration 4 - Site Survey 5 - Advanced Configuration X - Exit customer >>>
For the Decrement Hopping Frequencies set,
pressed the figure 5 (Advanced Configuration), then pressed the figure 2 (Interface Parameter Water),
then pressed the letter G (Decrement Hopping Frequencies),
then pressed the figure 1 (Enable).
Back to the main menu.
The set of CIR and MIR Parameters,
pressed the figure 5 (Advanced Configuration),
then pressed the figure 6 (Service Parameters),
then pressed the figure 2 (MIR And CIR Parameters).
NetLink/SU-A/E-BD Official Release Version - 4.1.34 Release Date: Sun Feb 02 16:21:33 2003 MIR And CIR Parameters ====================== 1 - MIR/CIR Option 2 - MIR: AU to SU 3 - MIR: SU to AU 4 - CIR: AU to SU 5 - CIR: SU to AU 6 - Maximum Delay 7 - Maximum Burst Duration S - Show MIR/CIR Parameters customer >>>
Press the figure 1 (MIR/CIR Option),
then pressed 1 (Enable)pressed the figure 2 (MIR: AU to SU),
put the figure of 1024pressed the figure 3 (MIR: SU to AU),
put the figure of 1024pressed the figure 4 (CIR: AU to SU),
put the figure of 1024pressed the figure 5 (CIR: SU to SU),
put the figure of 1024Back to the main menu.
To keep all the configurations was available, we must the re-set of NERA equipment, his method pressed the figure 2 (the Control Unit),
then pressed the figure 1 (Re- Set of the Unit),
then pressed again the figure 1 (Re- Set system now).
NetLink/SU-A/E-BD Official Release Version - 4.1.34 Release Date: Sun Feb 02 16:21:33 2003 Unit Control ============ 1 - Reset Unit 2 - Defaults Settings 3 - Change Unit Name 4 - Change Password 5 - Flash Memory Control 6 - Console Speed 7 - Log Out Timer 8 - Event Log Menu 9 - Auto Configuration Parameters A - SNMP Read ESSID customer >>> 1 0 - Cancel request 1 - Reset system now Enter exactly 1 decimal digits Allowed range is 0 to 1. >1
To know whether NERA Radio that was installed the connection to Base Stationnya, from main Menu pressed the figure 4 (Site Survey),
then pressed again the figure 4 (Continuous Link Quality Display).
If having his connection, then emerged AvrRssi and Error Rate, if still has not connected, then will emerge Link quality Is the note available (the Unit Is the Associated note).

No comments: